Page 255 - Praxair - Specialty Gases and Equipment Reference Guide
P. 255
3022 Regulators
High Purity Regulators for Corrosive Service
Single Stage 316 Stainless Steel Barstock Body,
Four-Port Configuration, 316 Stainless Steel
Diaphragm
The 3022 Series regulators are intended for primary pressure
control of high purity and corrosive gases. It is recommended for
applications where minor fluctuations in outlet pressure due to
diminishing inlet supply can be tolerated.
Typical Applications
■ Gas and liquid chromatography ■ High purity chamber
■ Ultra high purity carrier gases pressurization
■ Zero, span, and calibration ■ Liquefied hydrocarbon gas
gases control
■ Control of cryogenic gases
Features and Benefits
■ 316 Stainless Steel ■ Front and Rear Panel ■ Outlet Pressure Ranges ■ Low Wetted Volume
Barstock Body Mountable 0-15 to 0-500 psig Minimal purge requirements
Enhanced corrosion Versatile system configuration Broad range of applications
resistance Rear mount 10-32 UNF (2) ■ Convoluted diaphragm
■ 316L Stainless Steel Smooth pressure transition
■ 10 Micron Filtration Diaphragm
Failsafe seat performance No inboard diffusion
Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FNPT 316 stainless steel barstock 10 micron 316 stainless steel
■ Temperature Range ■ Helium Leak Integrity ■ Bonnet ■ Diaphragm
-40 °F to 165 °F 1 x 10 scc/sec 316 stainless steel barstock 316 stainless steel
-8
(-40 °C to 74 °C)
■ Cv ■ Seat ■ Internal Seals
■ Gauges 0.1 PFA Teflon ® Teflon ®
2" diameter stainless steel
■ Weight
3.2 lb (1.5 kg)
Ordering Information – Series PRS3022ABCD-CGA Highlighted selection indicates most popular model
Section E – Gas Handling Equipment
A B C D CGA*
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections*
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FNPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MNPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 30"-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MNPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 5: Needle Valve 1/4" MNPT
6: 1/8" Tube Fitting
7: 3/8" Tube Fitting
8: Diaphragm Valve 1/8" Tube Fitting
9: Diaphragm Valve 1/4" FNPT
Option Part Number Description
Panel Mount Kit PRS5500002T To mount the regulator using threads on the bonnet.
Captured Vent – Standard Equipment PRSSG6705 For easy piping of vented gases to a safe location in the event
3000 and 4000 1/16" FNPT of diaphragm failure.
Helium Leak Certification PRS4760002 Inboard helium leak certification to less than 1 x 10 scc/sec
-8
Protocol Station Add Letter “M” after CGA See page E •281 for details
Protocol Switchover Station Add Letter “C” after CGA See page E •282 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page E •283 for details
Protocol Alarm Station Add Letter “A” after CGA See page E •283 for details
Deep Purge Add Letter “D” after CGA See page E •279 for details
E•254 1-877-PRAXAIR www.praxairdirect.com