Accessories

            Emergency Shutdown Systems




            Emergency Shutdown Systems (ESS)
            At Praxair, a commitment to safety is a critical consideration
            in all of our activities. Helping maintain a level of safety for our
            employees and our customers is one of our top priorities. To
            help our customers achieve this goal, we have developed
            a series of emergency shutdown system controllers. These
            systems can be used in a wide variety of applications and are
            tailored to fit most applications.
            A typical shutdown system can include any of the components
            and configurations shown below. We also can custom engineer
            a system to meet your requirements.
            The most common uses of these types of systems include
            Toxic, Flammable and Corrosive Gas and Liquid Services,
            where the unintentional release of gas or liquid could result in
            personnel injury or equipment damage.
            To find out more about Emergency Shutdown Systems or to   Pneumatic Shut Down Controller
            have one engineered to fit your specific needs, please contact   Use discrete pressure set points to shut down a pneumatic
            your Praxair representative or call 1-877-PRAXAIR.    process valve or close the entire system with ESO push button.





















     Section E – Gas Handling Equipment
















            Emergency Gas Shutdown System                       Facilities Requirements
            Close individual or all pneumatic process valves with gas    n  100/115/220V ~ ± 10%, 50/60Hz, 0.2/A0.2/0.1 24 V ± 10%,
                                                                  0.5A VDC
            detection control signal, or with master ESO button. Used    n  Main supply voltage fluctuations not exceeding ± 10% of nominal
            with highly toxic, flammable, or where oxygen displacement   n  DC supply voltage fluctuations not exceeding ± 10% of nominal
            monitoring is required. System can be expanded to control up   Pilot Air Nitrogen
            to eight control valves. Requires use of a Praxair approved gas   n  Required 80-90 psig to supply ESO/Alarm Shut Down Controller.
            detection system and controller.                      1/4" OD poly tubing to connect ES controller pneumatic signals to
                                                                  process valves (normally closed/fail safe valves required)