Page 391 - Praxair - Specialty Gases and Equipment Reference Guide
P. 391

Gas Detection Systems

            Single Channel Wall Mount Controller




            The Beacon 110
            The Beacon 110 is a powerful, low cost fixed system controller for
            one point of gas detection. It is microprocessor controlled, versatile,
            simple to install and operate, and priced to be the industry’s best
            value single gas detection controller. It is capable of accepting RKI
            sensors directly for LEL level combustibles, Oxygen, CO 2 , and toxic
            gas sensors. The Beacon 110 can also accept any 4-20 mA trans-
            mitter (2 or 3 wire, 24 VDC). Sensors can be mounted directly at the
            Beacon 110 housing, or can be wired remote from the controller.
            Two 10 amp rated relay contacts allow direct control of external
            alarms and horns. The digital display has backlighting and
            simultaneous readout of the gas type and concentration.
            The Beacon 110 is also housed in a NEMA 4X rated case for a
            weather tight seal. This case design complies with lock out/tag out
            standards and can be fully secured. An external reset switch allows
            the alarm to be silenced from outside of the controller housing.
            The Beacon 110 ships complete with a wall mounting kit for easy
            installation.
            RKI offers the industry’s widest selection of standard and toxic gas
            detection sensors, all of which can be utilized with the Beacon 110,
            providing gas monitoring protection for almost any application.

              Features                                           Applications
            n  Low cost versatile solution  n  Accepts any 4-20 mA    n  Petrochemical plants
            n  Compact, weatherproof,      transmitter         n  Refineries            n  Parking garages
              NEMA 4X enclosure      n  Audible alarm with reset button  n  Water and wastewater treatment    n  Manufacturing facilities
            n  115/220 VAC or 24 VDC    n  Two programmable alarm levels    plants      n  Steel
              operation              n  Built-in trouble alarm with relay  n  Pulp and paper mills  n  Automotive
            n  Long life sensors     n  Relay rating 10 amps, form C  n  Gas, telephone, and electric     n  HVAC
              (2+ years typical)                                 utilities
            n  Accepts RKI LEL/O 2 /CO 2 /toxic    n  Provides 4-20 mA output
              direct connect sensors  n  Optional Strobe


              Specifications
     Section E – Gas Handling Equipment
            Physical                 Operating Environment     Inputs, continued        Outputs, continued
            n  Dimensions            n  Operating Temperature    n  Sampling Methods    n  Display
              Height: 8.5" (216 mm)      -4 °F to 122 °F (-20 °C to 50 °C)    Diffusion and sample draw     2 x 8 Alphanumeric display with
              Width: 7.0" (178 mm)                               heads available          backlighting
              Depth: 4.3" (109 mm)   n  Storage Temperature                             n  Audible
                                       -4 °F to 158 °F (-20 °C to 70 °C)
            n  Enclosure             n  Relative Humidity      Outputs                    Built-in audible alarm, 94 dB,
              Wall mounting grey fiberglass       0 - 95% RH (non-condensing)  n  Relays    mounted on enclosure.
              with hinged cover                                  Three relays – 10 amp rating      Coded output:
                                     n  Enclosure Rating         (at 115 VAC), SPDT isolated        pulsing = gas alarm,
            n  Conduit Connection      NEMA-4X enclosure, chemical,      contacts. 2 relays for gas alarms
              3/4" NPT conduit hubs,      and weather resistant    and 1 trouble relay. Relays fully    steady = fail
              2 provided. 1 for sensor wiring                    programmable for: increasing     n  Visual
              and 1 for power & relay wiring  Inputs             or decreasing alarm, latching or      3 LED’s on the front cover
            n  Wiring Termination    n  Direct Wired Sensors     self reset, normally energized       for alarm status indication,
              Screw type terminal block,      LEL, Oxygen, Carbon Dioxide,      or normally de-energized, time    and malfunction. Optional
              14 gauge max.            and toxic gas sensors. Remote      delay for alarm on and alarm off.    top-mount strobe
            n  Power                   amp not required for less than     n  4-20 mA    n  Warranty
              Universal 115 VAC & 220 VAC,      500 feet         Signal output, 4-20 mA      One year materials and
              or 24 VDC nominal, battery     n  4-20 mA Sensors     (maximum load impedance      workmanship
              backup option available    Accepts any 4-20 mA trans-       500 ohms), per channel
            n  Controls                mitter (24 VDC, 2 or 3 wire).      n  24 VDC
              3 internal push buttons for      A wide variety of RKI/Riken      24 VDC (400 mA max) output
              setup, programming, and      sensors are available with    provided to operate sample
              calibration. 1 external push      4-20 mA signals. Wiring      drawing adapters or other
              button for alarm reset.    distances up to 8,000 feet    accessories