Page 267 - Praxair - Specialty Gases and Equipment Reference Guide
P. 267

4092 and 4093 Regulators

            High Inlet/Outlet Pressure for Corrosive or Non-Corrosive Gases




            Piston-Sensed Single Stage Regulator
            for Ultra High Pressure Service
            Nickel-Plated Brass Body (4092 Series)
            316 Stainless Steel Body (4093 Series)
            The 4092 (Nickel-Plated Brass) and 4093 (316 Stainless Steel)
            Series regulators are intended for primary pressure control of
            non-corrosive gases at a maximum inlet pressure of 6000 psig.


              Typical Applications
            ■  Airplane strut charging  ■  Aerospace hydraulic systems
            ■  Research and development     ■  Pharmaceutical manufacturing
              laboratories           ■  Gauge calibration
            ■  Chemical manufacturing



              Features and Benefits
            ■  Large Piston Sensors   ■  Barstock Body         ■  Pressure Ranges       ■  Low Wetted Surface Area
              Safely controls pressure    Smooth surface finish    0-750 to 0-6000 psig    Minimal purge requirements
              to 6000 psig                                      Broad range of applications
                                     ■  Front and Rear Panel
                                       Mountable               ■  Four Port Design
                                       Versatile system configuration     Flexible installation alternatives

              Specifications                                     Materials
            ■  Maximum Inlet Pressure  ■  Gauges               ■  Body                  ■  Seat
              6000 psig (420 bar)      2-1/2" diameter chrome-plated    Nickel-plated brass or     Vespel
                                                                                              ®
                                       brass or 316 stainless steel    316L stainless steel barstock
            ■  Temperature Range                                                        ■  Filter
              -40 °F to 165 °F       ■  Cv                     ■  Bonnet                  10 micron
              (-40 °C to 74 °C)        .02 – 0-750 psig         Nickel-plated brass     ■  Internal Seals
                                       .06 – 0-2500 psig
            ■  Ports                                                                      Viton ®
              1/4" FNPT (gauges)       .12 – 0-6000 psig
                                     ■  Weight
                                       5.9 lb (2.7 kg)
              Ordering Information –
              Series PRS4092ABCD-CGA (Nickel-Plated Brass Body) and Series PRS4093ABCD-CGA (316L Stainless Steel Body)
     Section E – Gas Handling Equipment
              A                               B                     C                 D               CGA
            Outlet Pressure   Outlet Gauge   Inlet Pressure   Inlet Gauge   Outlet Assemblies   Assembly/Gauges   Inlet Connections
            1:  0-750 psig   0-1000 psig   0:  6000 psig (maximum)   None   0:  1/4" FNPT Port   0:  Bare Body   CGA,
            2:  0-1500 psig   0-4000 psig   3:  3000 psig (maximum)   0-4000 psig   1:  1/4" MNPT   1:  Standard Assembly   DIN 477,
            3:  0-2500 psig   0-4000 psig   8:  5500 psig (maximum)   0-6000 psig   2:  1/4" Tube Fitting      (psi/kPa Gauges)   BS 341
            4:  0-4500 psig*   0-6000 psig   9:  6000 psig (maximum)   0-10,000 psig   5:  Needle Valve 1/4" MNPT   2:  Standard Assembly   and others
            5:  0-6000 psig*   0-10,000 psig                     6:  1/8" Tube Fitting      (psig/BAR Gauges)   available
                                                                 7:  3/8" Tube Fitting
            * Not available with 3000 psig maximum inlet pressure.

              Option                         Part Number             Description
            Protocol Station                 Add Letter “M” after CGA   See page E •281 for details
            Protocol Switchover Station      Add Letter “C” after CGA   See page E •282 for details
            Protocol Switchover Station with Alarm   Add Letter “G” after CGA   See page E •283 for details
            Protocol Alarm Station           Add Letter “A” after CGA   See page E •283 for details
            Deep Purge                       Add Letter “D” after CGA   See page E •279 for details











           E•266                              1-877-PRAXAIR                     www.praxairdirect.com
   262   263   264   265   266   267   268   269   270   271   272