3013 Regulators

                                              High Purity Regulators for Oxygen Service




            Dual Stage Nickel-Plated Brass Barstock Body,
            Four-Port Configuration, Monel Diaphragm
            The 3013 Series regulators are intended for primary pressure
            control of oxygen, high purity gases. It is recommended for
            applications requiring constant delivery pressure control,
            regardless of supply pressure. It has been designed using
            only materials compatible for use In O 2  service.


              Typical Applications
            ■  Gas and liquid chromatography    ■  Petro/Chemical Industry
              FID, GC, HID, PID, FPO, RD,     ■  Purge gases
              ECD
            ■  Ultra high purity carrier gases  ■  Laboratory analysis
            ■  Zero, span, and calibration
              gases

              Features and Benefits
            ■  Nickel-Plated Brass   ■  10 Micron Filtration   ■  Monel Diaphragm       ■  Convoluted Diaphragm
              Barstock Body          ■  Outlet Pressure Ranges     No ignition source for higher       Smooth pressure transition
              Controlled surface integrity    0-15 to 0-250 psig    flows
            ■  Front Panel Mountable    Broad range of applications  ■  Low Wetted Volume
              Easy Installation                                 Minimal purge requirements

              Specifications                                     Materials
            ■  Maximum Inlet Pressure  ■  Ports                ■  Body                  ■  Filter
              3000 psig (210 bar)      1/4" FNPT                Nickel-plated brass barstock    10 micron sintered bronze
            ■  Temperature Range     ■  Helium Leak Integrity  ■  Bonnet                ■  Diaphragm                Section E – Gas Handling Equipment
              -40 °F to 165 °F         1 x 10  scc/sec          Nickel-plated brass barstock    Monel
                                           -8
              (-40 °C to 74 °C)
                                     ■  Cv                     ■  Seat                  ■  Internal Seals
            ■  Gauges                  .05                      First Stage – Teflon ®    Teflon ®
              2" diameter                                        Second Stage – PTFE
              chrome-plated brass    ■  Weight
                                       4.8 lb (2.2 kg)
              Ordering Information — Series PRS3013ABCD-CGA       Highlighted selection indicates most popular model

              A                               B         C                        D                  CGA
            Outlet Pressure   Outlet Gauge   Inlet Gauge   Outlet Assemblies   Assembly/Gauges   Inlet Connections
            1:  0-15 psig   30"-0-30 psig   0:  None   0:  1/4" FNPT Port      0:  Bare Body     540
            2:  0-50 psig   30"-0-100 psig   3:  0-4000 psig   1:  1/4" MNPT   1:  Standard Assembly
            3:  0-100 psig   30"-0-200 psig   5:  0-1000 psig   2:  1/4" Tube Fitting      (psi/kPa Gauges)
            4:  0-250 psig   0-400 psig   6:  0-300 psig   3:  Diaphragm Valve 1/4" Tube Fitting   2:  Standard Assembly
            7:  0-150 psig   30"-0-200 psig   7:  0-400 psig   4:  Diaphragm Valve 1/4" MNPT      (bar/psi Gauges)
                                                     5:  Needle Valve 1/4" MNPT
                                                     6:  1/8" Tube Fitting
                                                     7:  3/8" Tube Fitting
                                                     8:  Diaphragm Valve 1/8" Tube Fitting
                                                     9:  Diaphragm Valve 1/4" FNPT

              Option                         Part Number             Description
            Panel Mount Kit                  PRS5500002T             To mount the regulator using threads on the bonnet.
            Captured Vent – Standard Equipment   PRSSG6705           For easy piping of vented gases to a safe location in the event
            3000 and 4000 1/16" FNPT                                 of diaphragm failure.
            Protocol Station                 Add Letter “M” after CGA   See page E •281 for details
            Protocol Switchover Station      Add Letter “C” after CGA   See page E •282 for details
            Protocol Switchover Station with Alarm     Add Letter “G” after CGA   See page E •283 for details
            Protocol Alarm Station           Add Letter “A” after CGA   See page E •283 for details
            Deep Purge                       Add Letter “D” after CGA   See page E •279 for details