Page 289 - Praxair - Specialty Gases and Equipment Reference Guide
P. 289

8000 Gas Delivery System

            Dewar and High Pressure Cylinder Changeover System




                   ™
            ProSpec  Series 8000 Automatic Dewar and
            High Pressure Cylinder Changeover System
            The Series 8000 Automatic Changeover System is designed to
            provide an uninterrupted flow of gas from two sources, when lower
            flow requirements are needed. When one source is in service provid-
            ing the gas to process; the other source is on standby, and comes
            on line when the current source has depleted. The changeover to
            the standby source occurs automatically. Once the changeover has
            occurred, a gas technician replaces the depleted source, turns the
            changeover regulator hand knob to the next standby source.
            The Series 8000 system includes a line regulator to allow adjustment
            of the final delivery pressure to the process. Also included are 6'
            stainless steel armor-jacketed flexible pigtails, with CGA check valves,
            cylinder isolation and vent valves. This configuration gives the operator
            the capability to isolate a source from the changeover panel, allowing
            replacement of the source without having to shut down the system.


              Features and Benefits
            n  Integral Line Regulator  n  User Friendly Priority Valve
              Constant delivery pressure    Single lever operation
            n  6' Stainless steel pigtails  n  Check Valves
              Easy cylinder connections    Helps prevent backflow
            n  Preset Dual Back Pressure  n  Automatic Changeover
              Regulators               Continuous gas supply
              Allows gas flow to enter the
              process piping         n  Panel Mounted
                                       Easy installation
              Specifications           Materials
            n  Maximum Inlet Pressure  n  Bodies
              Dewar – 400 psig         Brass Barstock
              High pressure cylinder –   n  Diaphragms
              3000 psig                316L
            n  Outlet pressure Range
                                     n  Seats/Seals
              0-100 psig               PTFE
              Maximum flow @ 80 psig outlet
     Section E – Gas Handling Equipment
              25 slpm
            n  Temperature Range
              -40 °F to 148 °F
            n  Gauges
              2-1/2"

              Ordering Information – Series PRS8000
            Series    Model    A               B                 C             D
            Number            Number of Dewars    Number of Cylinders   Options    CGA
            PRS      8000     1:  1            1:  1             1:  No Alarm    580
                              2:  2            2:  2             2:  Audio/Visual    320
                              3:  3            3:  3                           540
                                               4:  4
                                               5:  5
                                               6:  6
            Example Part Number                         Serial
            PRS8000-112580 = Basic changeover for       Number       A  C
            one dewar and one high pressure cylinder,      s          s  s
            with alarm and CGA 580.                    PRS8000-112580
                                                                s     s    s
                                                              Model   B    D


           E•288                              1-877-PRAXAIR                     www.praxairdirect.com