Page 284 - Praxair - Specialty Gases and Equipment Reference Guide
P. 284

Gas Delivery Systems

                                              Protocol Alarm Station




            5029 Protocol Alarm Station
            The 5029 Series Protocol Alarm Station combines the safety and
            features of a standard Protocol Station with the added security of
            a remote alarm system. The Protocol Alarm Station will provide
            an audio/visual warning when a cylinder is nearly depleted. The
            alarm set point is easily field adjustable to provide the level of
            security and notification required. A convenient side port allows
            the addition of a diaphragm valve for purging when changing
            cylinders.
            The Protocol Alarm Station systems are available in 316 stainless
            steel with a variety of gauge ranges (600 psig, 4,000 psig,
            6,000 psig, and 10,000 psig). The system comes complete with
            a Protocol Station, a 3-foot all  stainless steel pigtail with armor              Shown with
            casing, pressure switch gauge and remote alarm/power supply                       optional PRS4022
            in either 110 vac or 220 vac. It may be ordered separately or                     Regulator
            attached to any high purity regulator.                                            (see page E •248)




              Features and Benefits
            n  Plugged Port in Gas Block  n  Remote Alarm      n  Mountable to Any Surface    n  Metal-to-Metal Diaphragm
              Facilitates purging      Provides audible and visual     Easy installation    Seal
                                       warning of cylinder depletion                      Limits possibility of gas
            n  Pressure Switch Gauge                           n  Gas Block
              Provides visual warning of   n  Integral Check Valve    Helps maintain gas purity    contamination
              cylinder depletion       No internal contamination                        n  Low Wetted Surface Area
                                       during cylinder changeout                          Minimal purge requirements  Section E – Gas Handling Equipment

              Specifications                                     Materials
            n  Maximum Inlet Pressure  n  Temperature Range    n  Gas Block             n  Inlet Connection
              3000 psig (210 bar)      -40 °F to 140 °F         316L stainless steel barstock    1/4" brass or 316L
              4500 psig (300 bar) optional    (-40 °C to 60 °C)    Chrome plated brass oxygen       stainless steel
              6000 psig (380 bar) optional  n  Weight           service                 n  Flexible Pigtails
                                       3.5 lb (1.6 kg) less regulator  n  Check Valve O-Ring    316 stainless steel barstock
                                                                Viton ®                   Innercore – Monel  for
                                                                                                     ®
                                                                                          oxygen service
                                                               n  Bracket
                                                                304 stainless steel
              Ordering Information – Series PRS5029
            Part Number              Description
            PRS50291095-CGA          Protocol Alarm* maximum inlet 400 psig (600 psig gauge)
            PRS50291101-CGA          Protocol Alarm* for brass regulators maximum inlet 3,000 psig (4,000 psig)
            PRS50291103-CGA          Protocol Alarm* for stainless steel regulators maximum inlet 3,000 psig
            PRS50291121-CGA          Protocol Alarm* for stainless steel regulators maximum inlet 4,500 psig (6,000 psig)
            PRS50291133-CGA          Protocol Alarm* 6,000 psig (10,000 psig)
                                     * Intrinsic Safety Barriers required for flammable service

              Option                 Part Number              Description
            Protocol Alarm Station    Add letter “A” after regulator   For example, to order a PRS40221331-580 regulator
            with Regulator           part number              with a Protocol Alarm Station, the part number would be
                                                              PRS40221331-580A.











            1-877-PRAXAIR                     www.praxairdirect.com                                        E•283