Page 397 - Praxair - Specialty Gases and Equipment Reference Guide
P. 397

Gas Detection Systems

            Direct Connect Sensors





              Direct Connect Sensors Specifications – Non-Explosion Proof
                             O 2             H 2 S          CO              Toxics          CO 2
                             Oxygen          Hydrogen Sulfide   Carbon Monoxide             Carbon Dioxide
              Sensors
              Type           Galvanic cell    Electrochemical    Electrochemical    Electrochemical    Infrared
              Measuring Range    0 - 25% volume    0 - 100 ppm    0 - 300 ppm   See Chart Below   0 - 5000 ppm
                                                                                            0 - 5.0% volume
                                                                                            0 - 50% volume
                                                                                            0 - 100% volume
              Lower Detectable   0.1% Vol.    2% of full scale   2% of full scale   2% of full scale   2% of full scale
              Limit (LDL)
              Response Time (T-90)    20 seconds or less    35 seconds or less    35 seconds or less    60 seconds or less   30 seconds or less
              Accuracy       0.5% volume     +/- 5% of full scale   +/- 5% of full scale   +/- 5% of full scale   +/- 5% of full scale
              Life Expectancy    2 years with   2 to 3 years with   2 to 3 years with   2 to 3 years with   5 years plus with
                             normal service    normal service    normal service    normal service    normal service
              Operating Environment
              Location       Indoor or outdoor,    Indoor or outdoor,   Indoor or outdoor,   Indoor or outdoor,   Indoor or outdoor,
                             Class I, Div. 2   Class I, Div. 2   Class I, Div. 2   Class I, Div. 2   Class I, Div. 2
              Temperature    -4° F to 122 °F   -4° F to 122 °F   -4° F to 122 °F   14 °F to 104 °F   -4 °F to 122 °F
                             -20 °C to 50 °C   -20 °C to 50 °C   -20 °C to 50 °C   -10 °C to 40 °C   -20 °C to 50 °C
              Humidity       0 - 99% RH      0 - 99% RH     0 - 99% RH      0 - 99% RH      0 - 99% RH
                             non-condensing   non-condensing   non-condensing   non-condensing   non-condensing
              Housing
              Housing J-Box    Cast aluminum,    Cast aluminum,   Cast aluminum,   Cast aluminum,   Cast aluminum,
                             explosion-proof
              Sensor         Stainless steel,   Stainless steel,   Stainless steel,   Stainless steel,   Stainless steel,
                             explosion-proof   explosion-proof   explosion-proof   explosion-proof   explosion-proof
              Controllers    Compatible with the following controllers: Beacon 110, Beacon 200, and Beacon 410
              Warranty       One year materials   One year materials   One year materials   One year materials   One year materials
                             and workmanship   and workmanship   and workmanship   and workmanship   and workmanship




              Ordering Information – Sensor With J-Box           Ordering Information – Sensor Only
            Description                  Part Number            Description                  Part Number
            O 2  Oxygen                  PRS65-2497RK           O 2  Oxygen                  PRS65-2494RK
     Section E – Gas Handling Equipment
            O 2  Oxygen                  PRS65-2502RK*          O 2  Oxygen                  PRS65-2510RK*
            H 2 S Hydrogen Sulfide       PRS65-2498RK           H 2 S Hydrogen Sulfide       PRS65-2495RK
            CO Carbon Monoxide           PRS65-2499RK           CO Carbon Monoxide           PRS65-2496RK
            CO 2  Carbon Dioxide (0 - 5000 ppm)   PRS61-1007RK-02  CO 2  Carbon Dioxide (0 - 5000 ppm)   PRS61-0198RK-02
            CO 2  Carbon Dioxide (0 - 5.0% volume)   PRS61-1007RK-03  CO 2  Carbon Dioxide (0 - 5.0% volume)   PRS61-0198RK-03
            CO 2  Carbon Dioxide (0 - 50% volume)   PRS61-1007RK-05  CO 2  Carbon Dioxide (0 - 50% volume)   PRS61-0198RK-05
            CO 2  Carbon Dioxide (0 - 100% volume)   PRS61-1007RK-10  CO 2  Carbon Dioxide (0 - 100% volume)   PRS61-0198RK-10
            *  Partial pressure sensor for helium (He) applications.    *  Partial pressure sensor for helium (He) applications.
             Consult your Praxair representative for details.    Consult your Praxair representative for details.


              Ordering Information – Toxic Sensor Transmitter (optional junction box)
            Part Number With J-Box    Part Number Without J-Box    Gas     Range
            65-2301RK-AsH3      65-2300RK-AsH3         Arsine (AsH 3 )     0 - 1.5 ppm
            65-2301RK-NH3       65-2300RK-NH3          Ammonia (NH 3 )     0 - 75.0 ppm
            65-2301RK-HCN       65-2300RK-HCN          Hydrogen Cyanide (HCN)    0 - 15 ppm
            65-2301RK-PH3       65-2300RK-PH3          Phosphine (PH 3 )    0 - 1.00 ppm
            65-2301RK-SO2       65-2300RK-SO2          Sulfur Dioxide (SO 2 )    0 - 6.00 ppm






           E•396                              1-877-PRAXAIR                     www.praxairdirect.com
   392   393   394   395   396   397   398   399   400   401   402