Gas Detection Systems

            Gas Sensor/Transmitter





              S2 Model Specifications – Non-Explosion Proof
                             O 2             H 2 S          CO              Toxics          CO 2
                             Oxygen          Hydrogen Sulfide   Carbon Monoxide             Carbon Dioxide
              Sensor
              Type           Galvanic cell    Electrochemical    Electrochemical    Electrochemical    Infrared
              Measuring Range    0-25% volume    0 - 100 ppm    0 - 300 ppm    See chart below   0 - 5000 ppm
                                                                                            0 - 5% volume
                                                                                            0 - 50% volume
                                                                                            0 - 100% volume
              Lower Detectable   0.1% volume    2% of full scale   2% of full scale   2% of full scale   2% of full scale
              Limit (LDL)
              Accuracy       ± 0.5% O 2      ± 5% of reading   ± 5% of reading   ± 10% of reading or   ± 5% of reading or
              (whichever is greater)         ± 2 ppm H 2 S   ± 5 ppm CO     ± 5% of full scale   ± 2% of full scale
              Life Expectancy    2 years with   2 to 3 years with   2 to 3 years with   2 to 3 years with    5 years plus with
                             normal service    normal service   normal service   normal service   normal service
              Response Time (T-90)    20 Seconds    45 Seconds    30 Seconds    60 Seconds    30 Seconds
              Operating Environment
              Location Indoor    Class I, Div. 2   Class I, Div. 2   Class I, Div. 2   Class I, Div. 2   Class I, Div. 2
              Temperature    -4 °F to 122 °F   -4 °F to 122 °F   -4 °F to 122 °F   14 °F to 104 °F   -4 °F to 122 °F
                             -20 °C to 50 °C   -20 °C to 50 °C   -20 °C to 50 °C   -10 °C to 40 °C   -20 °C to 50 °C
              Humidity       0-99% RH        0-99% RH       0-99% RH        5-95% RH        0-99% RH
                             non-condensing   non-condensing   non-condensing               non-condensing
              Housing
              Housing J-Box    Cast aluminum,   Cast aluminum,   Cast aluminum,   Cast aluminum,   Cast aluminum,
                             explosion-proof   explosion-proof   explosion-proof   explosion-proof   explosion-proof
              Sensor         Plastic or aluminum   Plastic or aluminum   Plastic or aluminum   Plastic or aluminum   Plastic or aluminum
              Controls
              Zero           Sets transmitter output to 4 mA with zero output from sensor
              Span           Sets transmitter output to 20 mA with full scale output from sensor
              Operating Voltage    19 VDC to 30 VDC   19 VDC to 30 VDC   19 VDC to 30 VDC   19 VDC to 30 VDC   19 VDC to 30 VDC
              Output         4-20 mA signal   4-20 mA signal    4-20 mA signal    4-20 mA signal    4-20 mA signal
              Controllers    Compatible with the following controllers: Beacon 110, Beacon 200, Beacon 410, and 800, also PLC and DCS systems
              Warranty       One year materials and workmanship



     Section E – Gas Handling Equipment
              Ordering Information                                Ordering Information –
                                                                  Non-Explosion Proof Toxic Assemblies
            Description                  Part Number
            O 2  Oxygen                  PRS65-2321RK           Part Number       Gas                Range
            H 2 S Hydrogen Sulfide       PRS65-2330RK           PRS65-2340RK-ASH3    Arsine (AsH 3 )    0 - 1.5 ppm
            CO Carbon Monoxide           PRS65-2335RK           PRS65-2340RK-NH3    Ammonia (NH 3 )    0 - 75 ppm
            CO 2  Carbon Dioxide (0 - 5000 ppm)   PRS65-2397RK-02  PRS65-2340RK-HCN    Hydrogen Cyanide (HCN)    0 - 15 ppm
            CO 2  Carbon Dioxide (0 - 5.0% volume)   PRS65-2397RK-03  PRS65-2340RK-PH3    Phosphine (PH 3 )    0 - 1.00 ppm
            CO 2  Carbon Dioxide (0 - 50% volume)   PRS65-2397RK-05  PRS65-2340RK-SO2    Sulfur Dioxide (SO 2 )    0 - 6.00 ppm
            CO 2  Carbon Dioxide (0 - 100% volume)   PRS65-2397RK-10



















           E•400                              1-877-PRAXAIR                     www.praxairdirect.com