Page 338 - Praxair - Specialty Gases and Equipment Reference Guide
P. 338
Purifiers/Filters
High and Low Pressure Purifiers
The SG6140 purifier is designed to remove water and/or oil from gas or liquid streams. It protects
sensitive instruments, prolongs service life and provides more accurate, reproducible test results.
This purifier may be used with non-corrosive gases compatible with brass and Viton at pressures up
®
to 3000 psig. Three different purifying elements are available (see Ordering Information and Optional
Equipment). These elements can be replaced without removing the purifier from the process line.
Specifications
n Maximum Operating n Dew Point Obtainable n Dimensions
Pressure 4A/13X Molecular Sieve: 5-11/16" H x 2" D
2000 psig 500 for O 2 -100 F (-75°C) n Mounting Holes (2)
o
n Pressure Drop n Inlet & Outlet Connections 1/4" 20UNC x 3/8" deep
1.0 psi at 56 slpm Air, 2.4 psi 1/4" FPT n Approximate Weight: 2 lb SG6140 Purifier Element
at 85 slpm Air
Materials
n Purifier n Purifier Element n Purifier Element n Purifier Element
Body and Cap: Aluminum/Brass Housing: Electrolytic Tin-Plated Retainer: Polyester Felt Backed Desiccant: 4A, 13X or
O-Ring Seal: Bonan Cold-Rolled Steel Type 316 SS Screen Activated Charcoal as ordered
Ordering Information Optional Equipment
Part Element Used for Water Capacity at Flow Part Replacement Elements
o
Number Type* Removing Rate of 2 scfm at 80 F Number and O-Ring
PRSSG6140 None N/A N/A PRSSG6141 Type 13X Molecular Sieve
PRSSG6140-1 Type 13X Molecular Sieve Oil and Water 6.5 grams PRSSG6142 Type 4A Molecular Sieve
PRSSG6140-2 Type 4A Molecular Sieve Water 7.2 grams PRSSG6143 Activated Charcoal
PRSSG6140-3 Activated Charcoal Oil and Heavy Hydrocarbons** N/A PRS0202-3268 Replacement Viton O-Ring
®
* Elements are shipped in individually packed, hermetically sealed cans to prevent deterioration.
They must be installed before using the purifier.
** Will remove trace amounts of Acetone in Acetylene.
Low Pressure, High Flow Purifier (Model AG6170) Section E – Gas Handling Equipment
The AG6170 purifier protects sensitive instruments from water and/or oil contamination which
ensures more accurate, reproducible test results and prolongs the instrument’s service life. This
purifier (capable of removing up to 20 times more water than our Model SG6140), may be used
with non-corrosive gases compatible with aluminum and neoprene at inlet pressures up to 350 psig.
Three different purifying elements are available (see Ordering Information and Optional Equipment).
These elements can be replaced without removing the purifier from the process line.
Specifications
n Maximum Operating n Maximum Flow Capacity n Dew Point Obtainable
Pressure 10 scfm for short periods (4A and 13X M.S.):
350 psig 1-3 scfm for extended use -100 F (1.5 ppm)
o
n Operating Temperature n Pressure Drop n Dimensions
Range 0.12 psi at 3 scfm 15-5/8" H x 4-3/4" D
-40 F to +200 F 1 psi at 7.5 scfm n Approximate Weight AG6170 Purifier,
o
o
n Inlet & Outlet Connections 4 lb Element and Gaskets
1/4" MPT
Materials
n Purifier n Purifier n Purifier Element n Purifier Element
Shell and Flange Plate: Strainer Assembly: Housing: Electrolytic Tin-Plated Desiccant: 4A, 13X or
Aluminum Monel and Brass Cold-Rolled Steel Activated Charcoal as ordered
Seals: Neoprene Retainer: Polyester Felt Backed
by Type 316 SS Screen
Ordering Information Optional Equipment
Part Number Element Type Used for Removing Water Capacity Part Number Replacement Element
PRSAG6170 None N/A N/A (includes replacement
PRSAG6170-1 Type 4A Molecular Sieve Water 134 grams gaskets)
PRSAG6170-2 Type 13A Molecular Sieve Oil and Water 126 grams PRSSG6171 Type 4A Molecular Sieve
PRSAG6170-3 Activated Charcoal Oil and Heavy Hydrocarbons** N/A PRSSG6172 Type 13X Molecular Sieve
* Elements are shipped in individually packed, hermetically sealed cans to prevent deterioration. PRSSG6173 Activated Charcoal
They must be installed before using the purifier.
** Not suitable for Acetylene service.
1-877-PRAXAIR www.praxairdirect.com E•337