Purifiers/Filters

                                              Oxygen Traps




            Disposable Oxygen Trap
            Praxair’s SG6160 Series Oxygen Traps are designed to remove
            trace levels of Oxygen from carrier gases such as Argon, Carbon
            Dioxide, Carbon Monoxide, Helium, Hydrogen, Methane or    SG6160 Oxygen Trap
            Nitrogen. These traps are also ideal for use with argon-methane
            mixtures (i.e. P-5 or P-10 mixtures), commonly used with gas
            chromatographs utilizing electron capture detectors.    Specifications
            These traps incorporate a highly reactive, metal reagent, which is
                                                               n  Maximum Operating
            supported on an inert substrate, coupled with molecular sieves.      Pressure   n  Maximum Flow Capacity
                                                                                          Model SG6160:
            Oxygen is removed by chemical reaction with the reagent to form     Model SG6160: 125 psig    5 slpm nitrogen at 125 psig
            a metal oxide. Oxygen levels can be effectively reduced to less     Model SG6162: 125 psig    Model SG6162-4:
            than 5 ppb when starting levels are 10 ppm or less.    To <5 ppb Oxygen when     20 slpm nitrogen at 80 psig
                                                               n  Efficiency
                                                                                          Model SG6162-2:
            Service life of these traps will vary depending on the incoming     inlet levels are 15 ppm or less     60 slpm nitrogen at 80 psig
            Oxygen level in the carrier gas. However, it is estimated that    n  Oxygen Capacity  n  Dimensions
            when the starting Oxygen level is <10 ppm, the Model SG6160     Model SG6160:      SG6160: 1-1/4" D x 10" L
                                                                260 cm  (345 mg)
                                                                     3
            can purify four cylinders (1200 ft ) of carrier gas, while the Model     Model SG6162:      SG6162: 2-3/8" D x 18" L
                                   3
                                                                                        n  Approximate Weight
            SG6162 can typically purify thirty-five cylinders (10,500 ft ) or     3 liters (3200 mg)    SG6160: 12 oz
                                                     3
            more. We also recommend, where the application’s flow rates                   SG6162: 3 lb
            permit, using these traps upstream of our SG6150 Series Indica-
            ting Oxygen Traps (below) to provide a visual indication of Oxygen     Materials
            breakthrough, thus alerting of the need to replace the trap.  n  Body       n  Filters (40 micron)
                                                                Aluminum                  Type 316 Stainless Steel
              Ordering Information                             n  Inlet and Outlet Fittings
                                                                Brass
            Part Number   Inlet and Outlet   Oxygen Capacity   Maximum Flow
                       Connections              Capacity       Note: Oxygen Traps are not recommended as a replacement for the use
            PRSSG6150-4  1/4" compression   22.5 cm  (30 mg)   10 slpm at 100 psi    of proper high purity gases. Rather, they are designed to provide additional
                                        3
            PRSSG6150-8  1/8" compression   22.5 cm  (30 mg)   10 slpm at 100 psi   protection from oxygen contamination which might result from system leaks
                                        3
                                                               or diffusion, or to achieve further reduction in oxygen impurity levels for    Section E – Gas Handling Equipment
                                                               extremely sensitive instrumentation or processes.
              Optional Equipment
            Part Number       Mounting Clip with screws
            PRSMC-2           For Model SG6150
                                                                Specifications
                                                              n  Maximum Operating      n  Dimensions
                                                                Pressure: 100 psig        SG6150:
                                                              n  Maximum Operating        1-1/4" D x 9-1/2" L
                                                                Temperature: 100  F       SG6151:
                                                                             o
                                                              n  Efficiency               1-3/8" D x 10-1/4" L
                   SG6150 Trap with                             To <1 ppb oxygen with   n  Approximate Weight
                   MC-2 Optional Mounting Clip                  inlet levels of 10 ppm or less     1 lb
                                                                 Materials
            Glass Encased, Indicating Oxygen Traps             n  Housing               n  Seals
            Models SG6150 and SG6151 Indicating Oxygen Traps are     Inner Tube:          Zytel-A Nylon Resin
                                                                Silanized Borosilicate Glass
            normally recommended for use downstream of non-indicating     Outer Tube:    n  Fittings
                                                                                          Nickel-Plated Brass
            oxygen traps (where application flow rates permit) to provide a      Polycarbonate Plastic  n  Filters (40 micron)
            visual indication of oxygen breakthrough. Breakthrough is                     Type 316 Stainless Steel
            indicated via a color change in the adsorbent from gray to a
            deep brown. Because of their relatively small capacity, Indicating     Ordering Information
            Oxygen Traps should be used by themselves only in low volume   Part Number   Inlet and Outlet Connections
            applications.                                     PRSSG6160-4       1/4" compression
                                                                                1/8" compression
                                                              PRSSG6160-8
            These traps consist of a silanized borosilicate glass tube filled    PRSSG6162-2   1/2" compression
            with a molecular sieve base and activated getter material.    PRSSG6162-4   1/4" compression
            Oxygen and a wide range of oxides react with the getter material
            to form a manganese oxide. The glass tube is enclosed in a clear     Optional Equipment
            plastic outer shell to provide protection from glass breakage while   Part Number   Mounting Clip
            still allowing for a visual indication of the trap’s condition.  PRSMC-1   For Model SG6160
                                                               PRSMC-5-2        For Model SG6162 (Set of 2)

            1-877-PRAXAIR                     www.praxairdirect.com                                        E•339
   335   336   337   338   339   340   341   342   343   344   345