Page 248 - Praxair - Specialty Gases and Equipment Reference Guide
P. 248
4032 Regulators
Critical Purity Regulators for Corrosive Service
Dual Stage 316 Stainless Steel
Barstock Body, Six- Port Configuration,
316 Stainless Steel Diaphragm
The 4032 Series regulators are intended for primary pressure
control of critical purity and corrosive gases. It is recommended
for applications requiring constant delivery pressure control,
regardless of supply pressure.
Typical Applications
■ EPA Protocol gases ■ High purity chamber
■ Gas and liquid chromatography pressurization
FID, GC, HID, PID, FPO, RD, ■ Petro/Chemical Industry
ECD ■ Purge gases
■ Ultra high purity carrier gases ■ Laboratory analysis
■ Zero, span, and calibration
gases
Features and Benefits
■ 316 Stainless Steel ■ Outlet Pressure Ranges ■ 316L Stainless Steel ■ Pipe Away Relief Valve –
Barstock Body 0-15 to 0-250 psig Diaphragm 1/4" FNPT
Enhanced corrosion resistance Broad range of applications No inboard diffusion Safely vent exhausted gases
■ Front Panel Mountable ■ Metal-to-Metal Diaphragm ■ Low Wetted Volume ■ Delivery Pressure Range
Easy installation Seal Minimal purge requirements Easily Changed
Reduces possibility of gas Maximum flexibility
contamination
Specifications Materials Section E – Gas Handling Equipment
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FNPT 316 stainless steel barstock 10 micron 316 stainless steel
4500 psig (300 bar) optional
■ Helium Leak Integrity ■ Bonnet ■ Diaphragm
-9
■ Temperature Range 1 x 10 scc/sec 316L stainless steel barstock 316 stainless steel
o
-40 F to 165 F
o
■ Seat
o
(-40 C to 74 C) ■ Cv First stage – PTFE Teflon ® ■ Internal Seals
o
0.05
Teflon
®
■ Gauges ■ Weight Second stage – CTFE with
2" diameter stainless steel 5.4 lb (2.5 kg) 4500 psig inlet option
Ordering Information – Series PRS4032ABCD-CGA Highlighted selection indicates most popular model
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig 30"-0-30 psig 0: None 0: 1/4" FNPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MNPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
7: 0-150 psig 30"-0-200 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MNPT (bar/psi Gauges) available
8: 0-6000 psig* 5: Needle Valve 1/4" MNPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
7: 3/8" Tube Fitting 5: Cleanroom Assembly
* Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with CTFE Seat 9: Diaphragm Valve 1/4" FNPT
Option Part Number Description
Panel Mount Kit PRS5500002T To mount the regulator using threads on the bonnet.
Captured Vent – Standard Equipment PRSSG6705 For easy piping of vented gases to a safe location in the event
3000 and 4000 1/16" FNPT of diaphragm failure.
Helium Leak Certification PRS4760002 Inboard helium leak certification to less than 1 x 10 scc/sec
-8
Protocol Station Add Letter “M” after CGA See page E •281 for details
Protocol Switchover Station Add Letter “C” after CGA See page E •282 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page E •283 for details
Protocol Alarm Station Add Letter “A” after CGA See page E •283 for details
Deep Purge Add Letter “D” after CGA See page E •279 for details
1-877-PRAXAIR www.praxairdirect.com E•247