Page 246 - Praxair - Specialty Gases and Equipment Reference Guide
P. 246
4002 Regulators
Critical Purity Regulators for Non-Corrosive Service
Single Stage Brass Barstock Body, Six-Port
Configuration, 316 Stainless Steel Diaphragm
The 4002 Series regulators are intended for primary pressure
control of non-corrosive, critical purity or liquefied gases. It is
recommended for applications where minor fluctuations in outlet
pressure due to diminishing inlet supply can be tolerated.
Typical Applications
■ Ultra high purity carrier gases ■ Liquefied hydrocarbon
■ Zero, span, and calibration gas control
gases ■ Control of cryogenic gases
■ High purity chamber
pressurization
Features and Benefits
■ Brass Barstock Body ■ Pressure Ranges ■ 316L Stainless Steel ■ Pipe Away Relief Valve –
Controlled surface integrity 0-15 to 0-500 psig Diaphragm 1/4" FNPT
Broad range of applications No inboard diffusion Safely vent exhausted gases
■ Front and Rear Panel
Mountable ■ Metal-to-Metal Diaphragm ■ Low Wetted Volume ■ Delivery Pressure Range
Versatile system configuration Seal Minimal purge requirements Easily Changed
Base mount 10-32 UNF (2) Reduces possibility of gas Maximum flexibility
contamination
Specifications Materials
■ Maximum Inlet Pressure ■ Ports ■ Body ■ Filter
3000 psig (210 bar) 1/4" FNPT Brass barstock 10 micron sintered bronze
4500 psig (300 bar) optional
■ Helium Leak Integrity ■ Bonnet ■ Diaphragm Section E – Gas Handling Equipment
-9
■ Temperature Range 1 x 10 scc/sec Brass barstock 316 stainless steel
o
o
-40 F to 165 F
■ Seat
o
(-40 C to 74 C) ■ Cv PFA Teflon ® ■ Internal Seals
o
0.1
Teflon
®
■ Gauges ■ Weight CTFE with 4500 psig
2" diameter brass 3.8 lb (1.7 kg) inlet option
chrome-plated
Ordering Information – Series PRS4002ABCD-CGA Highlighted selection indicates most popular model
A B C D CGA
Outlet Pressure Outlet Gauge Inlet Gauge Outlet Assemblies Assembly/Gauges Inlet Connections
1: 0-15 psig* 30"-0-30 psig 0: None 0: 1/4" FNPT Port 0: Bare Body CGA,
2: 0-50 psig 30"-0-100 psig 3: 0-4000 psig 1: 1/4" MNPT 1: Standard Assembly DIN 477,
3: 0-100 psig 30"-0-200 psig 5: 0-1000 psig 2: 1/4" Tube Fitting (psi/kPa Gauges) BS 341
4: 0-250 psig 0-400 psig 6: 0-300 psig 3: Diaphragm Valve 1/4" Tube Fitting 2: Standard Assembly and others
5: 0-500 psig 0-1000 psig 7: 0-400 psig 4: Diaphragm Valve 1/4" MNPT (bar/psi Gauges) available
7: 0-150 psig 30"-0-200 psig 8: 0-6000 psig** 5: Needle Valve 1/4" MNPT 4: Cleanroom Assembly
6: 1/8" Tube Fitting (psi/kPa Gauges)
* Not available with 4500 psig inlet pressure. 7: 3/8" Tube Fitting 5: Cleanroom Assembly
** Maximum inlet pressure 4500 psig (300 bar) 8: Diaphragm Valve 1/8" Tube Fitting (bar/psi Gauges)
with CTFE. 9: Diaphragm Valve 1/4" FNPT
Option Part Number Description
Panel Mount Kit PRS5500002T To mount the regulator using threads on the bonnet.
Captured Vent – Standard Equipment PRSSG6705 For easy piping of vented gases to a safe location in the event
3000 and 4000 1/16" FNPT of diaphragm failure.
Helium Leak Certification PRS4760002 Inboard helium leak certification to less than 1 x 10 scc/sec
-8
Protocol Station Add Letter “M” after CGA See page E •281 for details
Protocol Switchover Station Add Letter “C” after CGA See page E •282 for details
Protocol Switchover Station with Alarm Add Letter “G” after CGA See page E •283 for details
Protocol Alarm Station Add Letter “A” after CGA See page E •283 for details
Deep Purge Add Letter “D” after CGA See page E •279 for details
1-877-PRAXAIR www.praxairdirect.com E•245