4012 Regulators

            Critical Purity Regulators for Non-Corrosive Service




            Dual Stage Brass Barstock Body, Six-Port
            Configuration, 316 Stainless Steel Diaphragm
            The 4012 Series regulators are intended for primary pressure
            control of non-corrosive, critical purity or liquefied gases for
            applications requiring constant delivery pressure control,
            regardless of supply pressure.

              Typical Applications
            ■  EPA Protocol gases    ■  High purity chamber
            ■  Gas and liquid chromatography      pressurization
              FID, GC, HID, PID, FPO, RD,     ■  Petro/Chemical Industry
              ECD                    ■  Purge gases
            ■  Ultra high purity carrier gases  ■  Laboratory analysis
            ■  Zero, span, and calibration
              gases

              Features and Benefits
            ■  Brass Barstock Body   ■  Outlet Pressure Ranges   ■  316 Stainless Steel    ■  Pipe Away Relief Valve –
              Controlled surface integrity    0-15 to 0-250 psig    Diaphragm             1/4" FNPT
                                       Broad range of applications    No inboard diffusion    Safely vent exhausted gases
            ■  Front Panel Mountable
              Easy installation      ■  Metal-to-Metal Diaphragm     ■  Low Wetted Volume
                                       Seal                     Minimal purge requirements
                                       Reduces possibility of gas
                                       contamination

              Specifications                                     Materials
            ■  Maximum Inlet Pressure  ■  Ports                ■  Body                  ■  Filter
              3000 psig (210 bar)      1/4" FNPT                Brass barstock            10 micron sintered bronze
              4500 psig (300 bar) optional
                                     ■  Helium Leak Integrity  ■  Bonnet                ■  Diaphragm
                                           -9
            ■  Temperature Range       1 x 10  scc/sec          Brass barstock            316 stainless steel
                o
                       o
              -40  F to 165  F       ■  Cv                     ■  Seat                  ■  Internal Seals
                 o
                      o
              (-40  C to 74  C)        0.05                     First stage – PTFE Teflon ®    Teflon ®
            ■  Gauges                ■  Weight                   Second stage – CTFE with
              2" diameter brass        5.4 lb (2.5 kg)           4500 psig inlet option
              chrome-plated
     Section E – Gas Handling Equipment
              Ordering Information – Series PRS4012ABCD-CGA       Highlighted selection indicates most popular model
                 A                               B      C                        D                  CGA
            Outlet Pressure   Outlet Gauge   Inlet Gauge   Outlet Assemblies   Assembly/Gauges   Inlet Connections
            1:  0-15 psig   30"-0-30 psig   0:  None   0:  1/4" FNPT Port      0:  Bare Body     CGA,
            2:  0-50 psig   30"-0-100 psig   3:  0-4000 psig   1:  1/4" MNPT   1:  Standard Assembly   DIN 477,
            3:  0-100 psig   30"-0-200 psig   5:  0-1000 psig   2:  1/4" Tube Fitting      (psi/kPa Gauges)   BS 341
            4:  0-250 psig   0-400 psig   6:  0-300 psig   3:  Diaphragm Valve 1/4" Tube Fitting   2:  Standard Assembly   and others
            7:  0-150 psig   30"-0-200 psig   8:  0-6000 psig*   4:  Diaphragm Valve 1/4" MNPT      (bar/psi Gauges)   available
                                                     5:  Needle Valve 1/4" MNPT   4:  Cleanroom Assembly
                                                     6:  1/8" Tube Fitting        (psi/kPa Gauges)
                                                     7:  3/8" Tube Fitting     5:  Cleanroom Assembly
            *  Maximum inlet pressure 4500 psig          8:  Diaphragm Valve 1/8" Tube Fitting      (bar/psi Gauges)
               (300 bar) with CTFE                   9:  Diaphragm Valve 1/4" FNPT

              Option                         Part Number             Description
            Panel Mount Kit                  PRS5500002T             To mount the regulator using threads on the bonnet.
            Captured Vent – Standard Equipment   PRSSG6705           For easy piping of vented gases to a safe location in the event
            3000 and 4000 1/16" FNPT                                 of diaphragm failure.
            Helium Leak Certification        PRS4760002              Inboard helium leak certification to less than 1 x 10  scc/sec
                                                                                                    -8
            Protocol Station                 Add Letter “M” after CGA   See page E •281 for details
            Protocol Switchover Station      Add Letter “C” after CGA   See page E •282 for details
            Protocol Switchover Station with Alarm     Add Letter “G” after CGA   See page E •283 for details
            Protocol Alarm Station           Add Letter “A” after CGA   See page E •283 for details
            Deep Purge                       Add Letter “D” after CGA   See page E •279 for details