Page 247 - Praxair - Specialty Gases and Equipment Reference Guide
P. 247

4005 Regulators

            Critical Purity Regulators for Non-Corrosive Service




            Line Regulator, Single Stage Brass
            Barstock Body, Four-Port Configuration,
            316 Stainless Steel Diaphragm
            The 4005 Series regulators are intended for secondary pressure
            control of non corrosive, critical purity or liquefied gases. It is
            recommended as point of use pressure control in critical purity
            gas delivery systems.


              Typical Applications
            ■  Bulk gas delivery systems  ■  High purity chamber
            ■  Gas and liquid chromatography     pressurization
            ■  Ultra high purity carrier gases  ■  Liquefied hydrocarbon gas
            ■  Zero, span, and calibration     control
              gases                  ■  Control of cryogenic gases

              Features and Benefits
            ■  Brass Barstock Body   ■  Outlet Pressure Ranges   ■  316 Stainless Steel    ■  Pipe Away Relief Valve –
              Controlled surface integrity    0-15 to 0-500 psig    Diaphragm             1/4" FNPT
                                       Broad range of applications    No inboard diffusion    Safely vent exhausted gases
            ■  Front and Rear Panel
              Mountable              ■  Metal-to-Metal Diaphragm     ■  Low Wetted Volume  ■  Delivery Pressure Range
              Versatile system configuration    Seal            Minimal purge requirements    Easily Changed
              Base mount 10-32 UNF (2)    Reduces possibility of gas                      Maximum flexibility
                                       contamination

              Specifications                                     Materials
            ■  Maximum Inlet Pressure  ■  Helium Leak Integrity  ■  Body                ■  Filter
              3000 psig (210 bar)      1 x 10  scc/sec          Brass barstock            10 micron sintered bronze
                                           -9
            ■  Temperature Range     ■  Cv                     ■  Bonnet                ■  Diaphragm
                o
                       o
              -40  F to 165  F         0.1 (maximum outlet      Brass barstock            316 stainless steel
                 o
              (-40  C to 74  C)        50 psig or below)       ■  Seat                  ■  Internal Seals
                      o
                                       0.2 (maximum outlet             ®
            ■  Gauges                                           PFA Teflon                Teflon ®
              2" diameter brass        above 50 psig)
              chrome-plated          ■  Weight
                                       2.25 lb (1.0 kg)
            ■  Ports
              1/4" FNPT
     Section E – Gas Handling Equipment
              Ordering Information – Series PRS4005ABCD-CGA       Highlighted selection indicates most popular model
              A                               B         C                        D                  CGA
            Outlet Pressure   Outlet Gauge   Inlet Gauge   Outlet Assemblies   Assembly/Gauges   Inlet Connections
            1:  0-15 psig   30"-0-30 psig   0:  None   0: 1/4" FNPT Port       0:  Bare Body     000: 1/4" FNPT
            2:  0-50 psig   30"-0-100 psig           1:  1/4" MNPT             1:  Standard Assembly   TF2: 1/8" Tube
            3:  0-100 psig   30"-0-200 psig          2:  1/4" Tube Fitting        (psi/kPa Gauges)   TF4: 1/4" Tube
            4:  0-250 psig   0-400 psig              3:  Diaphragm Valve 1/4" Tube Fitting   2:  Standard Assembly   TF6: 3/8" Tube
            5:  0-500 psig   0-1000 psig             4:  Diaphragm Valve 1/4" MNPT      (bar/psi Gauges)   TF8: 1/2" Tube
            7:  0-150 psig   30"-0-200 psig          5:  Needle Valve 1/4" MNPT   4:  Cleanroom Assembly
                                                     6:  1/8" Tube Fitting        (psi/kPa Gauges)
                                                     7:  3/8" Tube Fitting     5:  Cleanroom Assembly
                                                     8:  Diaphragm Valve 1/8" Tube Fitting      (bar/psi Gauges)
                                                     9:  Diaphragm Valve 1/4" FNPT

              Option                   Part Number                Description
            Panel Mount Kit            PRS5500002T                To mount the regulator using threads on the bonnet.
            Wall Mount Bracket                                     PRSSMLR-1   To mount regulator to a wall.
            Captured Vent – Standard Equipment   PRSSG6705        For easy piping of vented gases to a safe location in the event
            3000 and 4000 1/16" FNPT                              of diaphragm failure.
            Helium Leak Certification   PRS4760002                Inboard helium leak certification to less than 1 x 10-8 scc/sec
            Reversed Inlet/Outlet Configuration   Contact your Praxair representative   Inlet and outlet ports supplied in a reversed (“mirror image”) configuration




           E•246                              1-877-PRAXAIR                     www.praxairdirect.com
   242   243   244   245   246   247   248   249   250   251   252