                                              Nitrogen






              Product/Grade     Purity   Part      Cylinder   O 2    H 2 0  CO 2    CO   THC   NOx   N 2 O   SO 2
                                Number   Style
              CEM Zero, 5.5     99.9995%*  NI 5.5CE   AS, AQ, A3   < 0.5  < 2  < 1   < 0.5   < 0.1   < 0.1   –   < 0.1
              Ultra Zero Ambient   99.999%*   NI 5.0UM   T, K, AS, AQ  < 2   < 2  < 0.5   < 0.1   < 0.5   < 0.02  –   < 0.005
              Monitoring, 5.0 (1)
              Volatile Organic   99.999%*   NI 5.0VC   AS, AQ, A3   < 2   < 2  < 0.3   < 0.01  < 0.1   –   –   < 0.01
              Compound Free, 5.0 (2)
              Ultra High Purity, 5.0   99.999%*   NI 5.0UH   T, K, Q,   < 1   < 3  –   –   < 0.5   –   –   –
              Vehicle Emission   99.998%*   NI 4.8VE   T, K, AS, AQ  < 0.5  < 1  < 1**   < 0.5   < 0.1   < 0.1   –   –
              Zero, 4.8 (3)
              Vehicle Emission   99.999%*   NI 5.01065   T, K, AS, AQ  ≤ 2   –   ≤ 10   ≤ 1   ≤ 0.05  ≤ 0.02    ≤ 0.02  –
              Zero (1065), 5.0
                         (4)
              *   Argon free basis.
              **  Available with 315-385 ppm CO 2  on request.
              (1)   SF 6  < 0.001 ppm.
              (2)   Can be individually analyzed for customer selected VOC components.
              (3)   Complies with Title 40 CFR 86 114.79. For other applications, alternative specifications may apply.
              (4)   Complies with Title 40 CFR Part 1065.750
              Other Nitrogen grades available upon request.
              Additional nitrogen grades are listed on page B •65.
              Concentrations given are ppm by volume unless otherwise specified.                                    Engine Emissions
              Maximum ppm unless otherwise noted.




            Multi-Gas Point-of-Use Panels                       High Purity Stainless Steel Tubing
            Praxair’s Multi-Gas Point-of-Use Panels             High purity piping systems utilize 316L stainless steel
            allow gases to be effectively pressure-             that is orbitally arc welded to ensure the cleanest delivery
            controlled to one or multiple instruments           system possible. High Purity Stainless Steel Tubing can be
            or use points in your test area. See page           designed and integrated into any analyzer configuration
            E•303 for complete details.                         and is EPA Part 1065 compliant. Contact your local
                                                                Praxair representative for details.




































            1-877-PRAXAIR                     www.praxairdirect.com                                        D•155
   151   152   153   154   155   156   157   158   159   160   161